contact@appliedbiotechnepal.com Phone/Whatsapp:
+977 9841706670 Disposable Backflush instrument, with blunt needle and passive aspiration.(20 gauge / 0.9 mm) 1281.AD
Sterile: Yes
Disposable Backflush instrument, with brush needle and passive aspiration.(20 gauge / 0.9 mm) 1281.BD
Sterile: Yes
Disposable Backflush instrument, with brush needle and active aspiration.(20 gauge / 0.9 mm) 1281.BTD
Sterile: Yes
Backflush sweeper with diamond dusted tip.(20 gauge / 0.9 mm) 1281.DDM
Sterile: Yes
Diamond dusted silicone tipped instrument with backflush capability foratraumatic tissue 'sweeping' combined with passive aspiration. Especially effective for use in PVR, relieving traction around macular holes and retinal tears, and for membrane manipulation with simultaneous aspiration of blood and vitreous matter Developed in collaboration with Richard Spaide, M.D. Disposable Shiraga Triamcinolone backflush instrument.(20 gauge / 0.9 mm) 1281.SD
Sterile: Yes
Disposable Backflush instrument, with extended silicone tip and active aspiration.(20 gauge / 0.9 mm) 1281.TDM
Sterile: Yes
Backflush Instrument with 20 gauge / 0.9 mm blunt needle. 2281.AD
Sterile: Yes Colour:
New ergonomical handle design to create optimal surgical control. Enlarged backflush reservoir. Overall more controlled and precise aspiration of intraocular fluids and/or debris. Disposable Backflush instrument, with blunt needle and passive aspiration.(23 gauge / 0.6 mm) 1281.AD06
Sterile: Yes
Disposable Shiraga Backflush instrument, with extendible brush tip and active aspiration. (23 gauge / 0.6 mm) 1281.SD06
Sterile: Yes
Disposable Backflush instrument, with brush needle and active aspiration.(23 gauge / 0.6 mm) 1281.BTD06
Sterile: Yes
Backflush Instrument with 23 gauge / 0.6 mm brush needle and active aspiration. 2281.BTD06
Sterile: Yes Colour:
New ergonomical handle design to create optimal surgical control. Enlarged backflush reservoir. Overall more controlled and precise aspiration of intraocular fluids and/or debris. Backflush Instrument with 23 gauge / 0.6 mm blunt needle. 2281.AD06
Sterile: Yes Colour:
New ergonomical handle design to create optimal surgical control. Enlarged backflush reservoir. Overall more controlled and precise aspiration of intraocular fluids and/or debris. Disposable High Myopic Backflush instrument, with brush needle and active aspiration. (23 gauge / 0.6 mm) 1281.BTDH6
Sterile: Yes
Indications for Use:
For operating on high myopic eyes. Features & Benefits:
Available in 23- and 25 Gauge formats. USP`'`s:
Five milimeter longer shaft than standard forceps. Backflush Instrument with 23ga / 0.6 mm soft-tip cannula and active aspiration 2281.STD06
Sterile: Yes Colour:
Slimline design for easier movement and control; Reduced size of the handle; Improved aspiration flow at high vacuum levels, especially for the smaller gauge sizes; Less force required to activate reservoir; Larger reservoir. Features & Benefits:
Available in 23- and 25 Gauge formats. Disposable Backflush instrument, with brush needle and active aspiration.(25 gauge / 0.5 mm) 1281.BTD05
Sterile: Yes
Backflush Instrument with 25 Ga / 0.5 mm brush needle and active aspiration 2281.BTD05
Sterile: Yes Colour:
New ergonomical handle design to create optimal surgical control. Enlarged backflush reservoir. Overall more controlled and precise aspiration of intraocular fluids and/or debris. Backflush Instrument with 25 Ga / 0.5 mm blunt needle and active aspiration 2281.AD05
Sterile: Yes Colour:
New ergonomical handle design to create optimal surgical control. Enlarged backflush reservoir. Overall more controlled and precise aspiration of intraocular fluids and/or debris. Disposable High Myopic Backflush instrument, with brush needle and active aspiration. (25 gauge / 0.5 mm) 1281.BTDH5
Sterile: Yes
Indications for Use:
For operating on high myopic eyes Features & Benefits:
Available in 23- and 25 Gauge formats. USP`'`s:
Available in 23- and 25 Gauge formats. Disposable Shiraga Backflush instrument, with extendible brush tip and active aspiration. (25 gauge / 0.5 mm) 1281.SD05
Sterile: Yes
Backflush Instrument with 25ga / 0.5 mm soft-tip cannula and active aspiration 2281.STD05
Sterile: Yes Colour:
Slimline design for easier movement and control; Reduced size of the handle; Improved aspiration flow at high vacuum levels, especially for the smaller gauge sizes; Less force required to activate reservoir; Larger reservoir. Backflush Instrument with 27 Ga / 0.4 mm blunt needle and active aspiration 2281.AD04
Sterile: Yes Colour:
Backflush instrument with 27 gauge / 0.4 mm brush needle and active aspiration 2281.BTD04
Sterile: Yes Colour:
New ergonomical handle design to create optimal surgical control. Enlarged backflush reservoir. Overall more controlled and precise aspiration of intraocular fluids and/or debris. Backflush instrument with 27ga/0.4 mm soft-tip cannula and active aspiration 2281.STD04
Sterile: Yes Colour:
Slimline design for easier movement and control; Reduced size of the handle; Improved aspiration flow at high vacuum levels, especially for the smaller gauge sizes; Less force required to activate reservoir; Larger reservoir.